{"id":2710,"date":"2024-05-18T09:46:21","date_gmt":"2024-05-18T06:46:21","guid":{"rendered":"https:\/\/fti.dp.ua\/conf\/?p=2710"},"modified":"2024-05-18T09:46:22","modified_gmt":"2024-05-18T06:46:22","slug":"05182-0945","status":"publish","type":"post","link":"https:\/\/fti.dp.ua\/conf\/2024\/05182-0945\/","title":{"rendered":"Experimental Study of Throttling of Solid Fuel Direct-Flow Steam Boilers"},"content":{"rendered":"\n<h1 class=\"wp-block-heading citation_title\">Experimental Study of Throttling of Solid Fuel Direct-Flow Steam Boilers<\/h1>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<h5 class=\"wp-block-heading citation_author\"><strong><strong><strong><strong><strong><strong><strong>Stanislav Bilohurov<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/h5>\n\n\n\n<p class=\"citation_author_url\"><em>ORCID: <a href=\"https:\/\/orcid.org\/0000-0002-2753-389X\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/orcid.org\/0000-0002-2753-389X<\/a><\/em><\/p>\n\n\n\n<p><em>Oles Honchar Dnipro National University<\/em><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:1em\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<h5 class=\"wp-block-heading citation_author\"><strong><strong><strong><strong><strong><strong><strong>Oleksandr Myshenko<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/h5>\n\n\n\n<p class=\"citation_author_url\"><em>ORCID: <a href=\"https:\/\/orcid.org\/0009-0003-7559-1407\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/orcid.org\/0009-0003-7559-1407<\/a><\/em><\/p>\n\n\n\n<p><em>Oles Honchar Dnipro National University<\/em><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:1em\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<h5 class=\"wp-block-heading citation_author\"><strong><strong><strong><strong><strong><strong><strong>Serhii Bardakov<\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/strong><\/h5>\n\n\n\n<p class=\"citation_author_url\"><em>ORCID: <a href=\"https:\/\/orcid.org\/0009-0001-9367-1414\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/orcid.org\/0009-0001-9367-1414<\/a><\/em><\/p>\n\n\n\n<p><em>Ukrainian State University of Chemical Technology<\/em><\/p>\n<\/div><\/div>\n\n\n\n<div style=\"height:1em\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The object of study of this work is the thermophysical processes of water boiling in narrow channels and its phase transition at variable heat flux and steam consumption. The use of traditional steam drum boilers is becoming more problematic, both in terms of safe operation and energy efficiency. This problem can be partially solved by using direct-flow steam boilers fuelled by solid fuel. The aim of the study is to determine the main operating modes of a steam boiler with a variable specific heat flux and variable steam flow over time of the required quality. The main task of direct-flow heat exchangers is to produce steam of proper quality: saturated, dry or superheated. The type of fuel used has a significant impact on this task. In the case of solid fuels, this process is complicated for several reasons: the calorific value of the fuel, its moisture content, the inertia of the combustion chamber and the loading device. A system for controlling steam generation of a certain quality was experimentally tested by dividing a straight-tube heat exchanger into two parts with a throttle washer: with superheated water at the inlet section of the heat exchanger and steam-liquid water at the boiler outlet. The control system monitored the pressure drop across the throttle washer depending on the steam flow rate, and the feedback was based on the steam temperature. The study found that with a slight change in steam flow and low frequency, it is possible to maintain the pressure at the outlet of the heat exchanger constant. Limiting external influences on the physical picture of water evaporation in a straight-tube evaporator and using a proportional-integral-differential (PID) controller made it possible to simplify the control system of a straight-tube steam boiler at different steam flow rates with a relatively stable pressure at the outlet of the heat exchanger.<\/p>\n\n\n\n<div style=\"height:18px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-right is-layout-flex wp-container-core-buttons-is-layout-765c4724 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/cims.fti.dp.ua\/j\/article\/view\/129\" target=\"_blank\" rel=\"noreferrer noopener\">FULL TEXT<\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:18px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-default\"\/>\n\n\n\n<div style=\"height:1em\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-right is-layout-flex wp-container-core-group-is-layout-b6c475e2 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-content-justification-right is-nowrap is-layout-flex wp-container-core-group-is-layout-fd526d70 wp-block-group-is-layout-flex\"><div class=\"taxonomy-post_tag wp-block-post-terms\"><a href=\"https:\/\/fti.dp.ua\/conf\/tag\/cims-2024-vernal\/\" rel=\"tag\">CIMS 2024 Vernal<\/a><\/div>\n\n<div class=\"wp-block-post-date\"><time datetime=\"2024-05-18T09:46:21+03:00\">May 18, 2024<\/time><\/div><\/div>\n\n\n<div class=\"taxonomy-category wp-block-post-terms\"><a href=\"https:\/\/fti.dp.ua\/conf\/session\/energy-2\/\" rel=\"tag\">Engines, Energy and Thermotechnics<\/a><\/div><\/div>\n\n\n\n<div style=\"height:1em\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-default\"\/>\n","protected":false},"excerpt":{"rendered":"<p>Experimental Study of Throttling of Solid Fuel Direct-Flow Steam Boilers Stanislav Bilohurov ORCID: https:\/\/orcid.org\/0000-0002-2753-389X Oles Honchar Dnipro National University Oleksandr Myshenko ORCID: https:\/\/orcid.org\/0009-0003-7559-1407 Oles Honchar Dnipro National University Serhii Bardakov ORCID: https:\/\/orcid.org\/0009-0001-9367-1414 Ukrainian State University of Chemical Technology The object of study of this work is the thermophysical processes of water boiling in narrow channels and its phase transition at variable heat flux and steam consumption. The use of traditional steam drum boilers is becoming more problematic, both in terms &hellip; <\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[30],"tags":[29],"class_list":["post-2710","post","type-post","status-publish","format-standard","hentry","category-energy-2","tag-cims-2024-vernal"],"_links":{"self":[{"href":"https:\/\/fti.dp.ua\/conf\/wp-json\/wp\/v2\/posts\/2710","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fti.dp.ua\/conf\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fti.dp.ua\/conf\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fti.dp.ua\/conf\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/fti.dp.ua\/conf\/wp-json\/wp\/v2\/comments?post=2710"}],"version-history":[{"count":1,"href":"https:\/\/fti.dp.ua\/conf\/wp-json\/wp\/v2\/posts\/2710\/revisions"}],"predecessor-version":[{"id":2711,"href":"https:\/\/fti.dp.ua\/conf\/wp-json\/wp\/v2\/posts\/2710\/revisions\/2711"}],"wp:attachment":[{"href":"https:\/\/fti.dp.ua\/conf\/wp-json\/wp\/v2\/media?parent=2710"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fti.dp.ua\/conf\/wp-json\/wp\/v2\/categories?post=2710"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fti.dp.ua\/conf\/wp-json\/wp\/v2\/tags?post=2710"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}